@QDeathNick

Как включить PI через megacli при замене диска?

При замене убитого диска через megacli получаю сообщение:
root@debian1:~# megacli -PdReplaceMissing -PhysDrv[252:1] -array0 -row1 -a0
Adapter: 0: Failed to replace Missing PD at Array 0, Row 1.
FW error description:
  'PDs in LD have incompatible EEDP types'
Exit Code: 0x63

Пытаюсь включить Protection Information(PI)
root@debian1:~# megacli CfgEachDskRaid0 -enblPI -a0
'PD Doesnt support PI'
Exit Code: 0x01

Как я понимаю, новый диск не поддерживает PI, либо она как-то выключена, не сконфигурирована на нём, а на старых всё включено и они отформатированы с поддержкой PI.

TOPOLOGY :
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace TR
-----------------------------------------------------------------------------
 0 -   -   -        -   RAID1 Dgrd  N  556.929 GB dsbl Y  N   dflt N      N
 0 0   -   -        -   RAID1 Dgrd  N  556.929 GB dsbl Y  N   dflt N      N
 0 0   0   252:0    13  DRIVE Onln  N  278.464 GB dsbl Y  N   dflt -      N
 0 0   1   -        -   DRIVE Msng  -  278.464 GB -    -  -   -    -      N
 0 0   2   252:2    11  DRIVE Onln  N  278.464 GB dsbl Y  N   dflt -      N
 0 0   3   252:3    10  DRIVE Onln  N  278.464 GB dsbl Y  N   dflt -      N
-----------------------------------------------------------------------------


У всех дисков видно PI type: 2
root@debian1:~# megacli -PDList -aALL

Adapter #0

Enclosure Device ID: 252
Slot Number: 0
Drive`s position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 13
WWN: 5000C5005A3A75E4
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.464 GB [0x22cee000 Sectors]
Sector Size:  512
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: B55C
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c5005a3a75e5
SAS Address(1): 0x0
Connected Port Number: 3(path0)
Inquiry Data: IBM-ESXSST9300605SS     B55C6XP4GY6T0808B55C
IBM FRU/CRU: 90Y8878
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive:  Not Certified
Drive Temperature :24C (75.20 F)
'PI Eligibility:  Yes
Number of bytes of user data in LBA: 512
Drive is formatted for PI information:  Yes
PI: PI with type 2'
Port-0 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No


У нового

Enclosure Device ID: 252
Slot Number: 1
Enclosure position: N/A
Device Id: 14
WWN: 5000C500741861C8
Sequence Number: 1
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS

Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.464 GB [0x22cee000 Sectors]
Sector Size:  512
Firmware state: Unconfigured(good), Spun Up
Device Firmware Level: B55C
Shield Counter: 0
Successful diagnostics completion on :  N/A
SAS Address(0): 0x5000c500741861c9
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: IBM-ESXSST9300605SS     B55C6XP2GJ8B0808B55C
IBM FRU/CRU: 42D0628
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive:  Not Certified
Drive Temperature :25C (77.00 F)
'PI Eligibility:  No
Drive is formatted for PI information:  No
PI: No PI'
Port-0 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port`s Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No

Перерыл уже всё, что смог найти, подскажите пожалуйста куда бы дальше покопать?
Как включить PI и заменить диск?
  • Вопрос задан
  • 358 просмотров
Решения вопроса 1
svalx
@svalx
Волгоград, эникейщик со стажем.
Нужно отключить PI для логического диска, без этого ребилд невозможен:
megacli -LDSetProp DsblPI -L0 -a0
Эта опция есть в megacli Ver 8.07.14.
Ответ написан
Пригласить эксперта
Ваш ответ на вопрос

Войдите, чтобы написать ответ

Войти через центр авторизации
Похожие вопросы